Why Is My Thermostat Suddenly Reading ‘Aux Heat’?
Did you just check your thermostat, notice a new notification, and immediately look to get your heat pump auxiliary heat explained? If so, you are certainly not alone. In our years of keeping Peterborough homes comfortable, we hear this exact concern from homeowners every winter. It is completely understandable to worry about sudden system failure and rising energy consumption when your primary heating mode appears to stop working. When that little “Aux Heat” light turns on, many homeowners immediately assume their compressor has broken down and brace themselves for a freezing house.
As winter approaches and temperatures plummet, our team at Kawartha Eco Climate Control sees this thermostat notification become a daily reality. Deep winter cold snaps in Ontario can push any residential heating equipment to its absolute limits. The big decision point you face right now is understanding whether this is a normal, designed system response to sub-zero temperatures or a legitimate sign of a malfunctioning compressor. Knowing the difference is the key to your peace of mind.
When you understand exactly how your system reacts to extreme weather, you know exactly when to let it run and when to reach out to our team for professional heat pump services. Let’s break down exactly what your system is doing, why it needs a backup plan, and how to tell if something is actually wrong.
The Basics: Heat Pump Auxiliary Heat Explained
The short answer is: Auxiliary heat (often labeled simply as “Aux Heat” on your thermostat) is your system’s built-in secondary heating source. It is an intended feature, not a bug or a sign of immediate failure.
To understand why this backup exists, it helps to know how your system works. Heat pumps do not generate heat by burning fuel the way a gas furnace does. Instead, they transfer heat from the outside air into your home. Even when it feels freezing outside, there is still thermal energy in the air. However, when there simply isn’t enough ambient heat left to pull from the outdoor air to keep your home at your desired temperature, the backup system automatically kicks in to bridge the gap.
The three main triggers that turn on auxiliary heat include:
- Outdoor temperatures dropping too low: When the weather gets extremely cold, the heat pump cannot extract enough heat to keep up with your home’s heat loss.
- The system entering a defrost cycle: Ice builds up on the outdoor unit in winter, and the system temporarily uses backup heat while it melts that ice away.
- A large manual thermostat increase: If you turn the thermostat up by several degrees all at once, the system uses the backup heat to reach the new temperature faster.
Seeing this message on your screen simply means your system is doing exactly what it was programmed to do to keep your family comfortable.
Understanding the Temperature Balance Point
To fully grasp why your system switches modes, we need to talk about the “balance point.” The balance point is the specific outdoor temperature where your heat pump’s maximum heating capacity exactly matches your home’s heat loss. Above this temperature, the heat pump can heat your home entirely on its own. Below this temperature, it needs help.
Standard heat pumps often reach their balance point between -1 C and 2 C. In our experience installing and servicing systems across Peterborough, we note that when sub-zero outdoor temperatures cross the heat pump balance point, the system automatically supplements its output with auxiliary heat to maintain indoor comfort. Modern cold-climate heat pumps are engineered differently and can operate efficiently down to -25 C before they rely heavily on their backup heating source. We frequently recommend these cold-climate models to maximize efficiency during Ontario winters, and homeowners should note that generic federal tax credits or energy rebates may apply to qualifying heat pump installations (we always advise readers to verify current programs with their utility or a tax professional).
Peterborough’s severe winter cold snaps frequently push temperatures well below the balance point of standard systems. When this happens, the transition to backup heat is seamless. You likely won’t even notice a change in the airflow or the temperature of your home—you will only notice the indicator light on your thermostat.
What Happens Mechanically Below the Balance Point?
When the outdoor temperature drops below that critical threshold, your thermostat sends a signal to engage the secondary heating element. The primary heat pump usually continues to run because it is still extracting some heat from the outside air. It is simply getting an assist. This dual-action approach ensures you stay warm without putting impossible strain on the outdoor compressor. If you are curious about how extreme cold affects heat pump efficiency, knowing your specific model’s balance point is the first step.

How Backup Heating Methods Differ in Extreme Cold
Not all auxiliary heat is created equal. Depending on how your home is set up, your backup heat will come in one of two main forms: electric resistance strips or a gas furnace. Understanding which type you have is important because they operate differently and have very different impacts on your monthly utility bills.
As Kawartha Eco Climate Control specialists, a pattern we see often is homeowners struggling with high winter hydro bills because their system isn’t tailored to their specific home. Over our years of working on local HVAC systems, we have developed extensive expertise in optimizing both hybrid and all-electric setups specifically for the demands of Ontario winters to help manage those hydro costs.
Electric Resistance vs. Gas Furnace Backup
Electric resistance strips act like a giant toaster inside your ductwork. They provide immediate, intense heat, but they draw heavy electrical amperage to do so. While electric resistance is technically 100% efficient (all the electricity is converted to heat), it uses significantly more electricity than the heat pump’s normal compressor cycle, which operates at 200% to 300% efficiency. Because of Ontario’s Time-of-Use hydro rates, the energy consumption of electric resistance heat is very noticeable if it runs constantly during peak winter hours.
On the other hand, hybrid heating systems (also known as dual-fuel systems) use a gas furnace as the backup. In these setups, the heat pump shuts down completely when it gets too cold, and the gas furnace takes over the entire heating load. Proper configuration by a licensed professional is critical to ensure the most cost-effective source runs at the right time.
| Feature | Electric Resistance Backup | Gas Furnace Backup (Dual-Fuel) |
|---|---|---|
| Energy Source | Electricity from your home’s breaker panel | Natural gas or propane |
| System Operation | Runs simultaneously with the heat pump | Takes over completely; heat pump shuts off |
| Efficiency Impact | High electricity draw; impacts hydro bills | Uses gas; avoids peak hydro rates |
| Best Use Case | Homes without gas lines; cold-climate models | Homes in areas with extreme, prolonged freezes |
The Defrost Cycle: A Temporary Auxiliary Trigger
What if it is a relatively mild winter day, well above your balance point, but your thermostat still briefly flashes “Aux Heat”? You might assume something is wrong, but when our technicians field calls about this, we usually explain that it is just the defrost cycle in action. All-electric heat pumps occasionally need to melt frost or ice buildup off the outdoor unit to keep air flowing freely through the coils.
Here is exactly what happens automatically during a normal defrost cycle:
- Frost detection: Sensors inside the outdoor unit detect that ice is beginning to form on the coils due to cold, damp winter air.
- Reversing the flow: The system briefly reverses its operation. It stops sending heat inside and instead sends warm refrigerant outside to melt the ice. (It essentially runs in air conditioning mode for a few minutes).
- Auxiliary heat activation: To prevent blowing freezing cold air into your living room while the outdoor unit defrosts, the system automatically turns on the auxiliary heat strips to warm the air before it comes out of your vents.
- Return to normal: Once the ice is melted, the system switches back to its normal, highly efficient heating mode, and the “Aux Heat” light turns off.
This entire process usually only takes 5 to 15 minutes. It is a short, self-correcting process and absolutely not a cause for alarm.
Normal Operation vs. System Malfunction: When to Worry
While our team has established that auxiliary heat is a normal part of winter operation, it is still possible for a heat pump to malfunction and rely on its backup heat when it shouldn’t. Recognizing the difference between normal deep-freeze operation and abnormal usage can save you a tremendous amount of money on your energy bills.
If your system is running on backup heat constantly, you are essentially heating your home with giant electric space heaters. Over time, that takes a toll. You need clear criteria for when to call our professionals for heat pump maintenance.
Watch out for these clear warning signs:
- Mild weather activation: The “Aux Heat” light stays on even when outdoor temperatures are mild and well above your system’s balance point (e.g., +5 C or higher).
- Unexplained hydro spikes: You receive unusually high energy bills that do not align with local weather patterns or extreme cold snaps.
- Failure to reach set temperature: The system runs constantly, the backup heat is engaged, but the house still feels chilly and fails to reach the temperature set on the thermostat.
- Short cycling: The system turns on and off very rapidly, never completing a full heating cycle, while frequently triggering the backup heat.
- Strange noises: You hear grinding, hissing, or loud buzzing coming from the outdoor unit while the indoor thermostat reads “Aux Heat.”
If you notice these symptoms, they usually point to a primary compressor issue, a failing reversing valve, or a refrigerant leak. These are complex mechanical issues that require professional diagnostics to resolve.
Frequently Asked Questions About Auxiliary Heat
Is it normal for auxiliary heat to come on?
Yes, it is entirely normal and designed to happen during extreme cold, defrost cycles, or sudden thermostat adjustments. Your heat pump uses this backup source to ensure your home stays warm when the primary compressor needs assistance. As long as it turns off when the weather warms up, your system is functioning correctly.
At what temperature should auxiliary heat turn on?
It depends on the system’s balance point, typically between -1 C and 2 C for standard units, or much lower for cold-climate models. When Ontario winter temperatures drop below this specific threshold, the heat pump can no longer extract enough heat from the outside air alone, triggering the backup system.
How do I know if my auxiliary heat is stuck on?
If the outdoor temperature is well above freezing and the thermostat still reads “Aux,” or if your energy bills spike unexpectedly during mild weather, it may be stuck. You might also notice that the air coming from your vents feels lukewarm rather than hot, indicating the primary compressor has stopped contributing entirely.
Does auxiliary heat use more electricity?
Yes, electric resistance auxiliary heat uses up to three times more electricity than the heat pump’s standard compression cycle. While a heat pump efficiently moves existing heat, electric backup strips must generate heat from scratch, drawing significant amperage and increasing your hydro costs during prolonged use.
What is the difference between emergency heat and auxiliary heat?
Auxiliary heat turns on automatically to supplement the heat pump; emergency heat is a manual setting turned on by the homeowner when the primary heat pump has completely failed. Flipping your thermostat to “Emergency Heat” locks out the outdoor compressor entirely and forces the system to rely 100% on the backup heating source.
Can I stop my heat pump from using auxiliary heat during an Ontario winter?
You cannot and should not fully disable it, as it is necessary for keeping your home warm when temperatures drop below the system’s balance point. If you disable the backup heat, your heat pump will run constantly during a deep freeze without ever reaching your desired indoor temperature, leading to heavy wear and tear.
Ensure Your Heat Pump is Ready for the Next Cold Snap
Understanding your system’s balance point provides a reassuring explanation for why backup heat is necessary when the weather turns harsh. While seeing that “Aux Heat” notification is completely normal during a deep freeze, recognizing the subtle differences between normal operation and a true malfunction saves you money and unnecessary stress.
You now have clear criteria for when to let the system do its job and when to call a professional. Don’t wait for your primary compressor to fail in the middle of a sub-zero night. If you suspect your backup heat is running more often than it should, or if you simply want to ensure your system is operating at peak efficiency, our team is here to help. Schedule a thorough inspection with Kawartha Eco Climate Control before the next major freeze hits Peterborough.